Avoid These 5 Common Mistakes When Testing Relative Humidity in Concrete Slabs
It is truly insane to think you can hack your way into a beautiful flooring installation without disastrous results unless you read up on and adhere to the ASTM F2170 standard. However, it’s not very hard to follow and the technology has made it easier than before. That being said, here are some “honest” mistakes we’d like to warn you about in advance:
- Not performing RH testing – This is bad. Don’t forget this really vital step in the flooring installation process.
- Assuming that one RH sensor will do the job. – You know what happens when you assume, right?
- Installing the RH sensor upside down. – No really, it’s happened.
- Trying to recover and reuse an RH sensor. – Going “Green” here is going too far. Besides, we have “reusable” sensors for that.
- Waiting 72 hours after installing RH sensors to take readings. The new rule is “24 hours” Read up on ASTM F2170. Don’t be old school.
If you are installing nearly any type of flooring material over a concrete slab, it’s going to be absolutely necessary that you have accurate concrete moisture test data that show relative humidity (RH) readings within the specifications laid out by the flooring material manufacturer. F2170 in situ probe testing has been proven to be the most reliable test method to determine the moisture condition of a concrete slab. But just like anything else, you need to be skilled in the proper use of the tools and know the procedures. The better prepared and the more experienced you are, the better your results will be.
But even with best-laid plans, mistakes still happen. Here are five cautionary tips that have come directly from Wagner Meters call center logs:
Mistake #1: Not Performing RH Testing
This is probably the worst mistake you can make. It just doesn’t make sense to skip RH testing for concrete. Just like neglecting any other diagnostic or measurement tool, the potential cost to your bottom line and to your reputation can be very high if things go south.
Wagner Meters takes great pride in providing personalized customer service to assist flooring professionals and help them be successful with concrete RH testing—sometimes even when they’re not using our well-known Rapid RH in situ testing system. We keep records of our more significant support calls. Here’s a cautionary tale from our files: A general contractor (GC), in charge of construction and renovation for a large school district, was making a 2,000 sq. ft. addition to his own home. Once the HVAC was up and running, the wood flooring was delivered. Because of the GC’s busy schedule, his home addition was a low priority, so the wood flooring had nine months to acclimate.
The GC subcontracted out the flooring installation, but the flooring contractor didn’t perform any RH testing on the concrete slab. Apparently, the GC didn’t fully understand at the time the importance of RH testing because the school district always hired inspection companies to do all the testing. So when the flooring contractor told him that the adhesive would act as a moisture barrier against any problem moisture, the GC gave the go-ahead for the installation. Two months later, the floor failed throughout the entire 2,000 sq. ft. of the addition. Lesson learned: do your own test to be sure. Even if another test has been done, two sets of results are better than one.
Mistake #2: Assuming That One RH Sensor Will Do the Job
We sometimes get calls from customers asking if one Rapid RH® Smart Sensor in a slab will do the job. The answer is no. ASTM F2170 10.1.1 states that you must perform three tests for the first 1,000 sq. ft. and at least one additional test per additional 1,000 sq. ft. The reason for this is that a concrete slab can exhibit a wide variation in moisture conditions due to things like staggered pouring times, irregular aggregate concentration and even exposure to sunlight. You don’t want that one untested section of the slab that was in the shade to ruin your entire flooring installation.
Mistake #3: Installing the RH Sensor Upside Down
Wagner Meters, a leading innovator in wood and concrete moisture detection systems since 1965, produces an in situ probe testing system that is compliant with ASTM F2170. Wagner’s Rapid RH L6 Smart Sensor is a cylindrical sleeve with a closed bottom. Although you might think the closed end should be at the top to enclose the test hole, it doesn’t work that way. The closed end goes in first, and traps a very small volume of air between the bottom of the sleeve and the bottom of the hole inside what is called an “isolation gasket.” That volume of air is where the RH reading is taken by the onboard electronic sensor. Follow the instructions carefully. Once you’ve installed the sensor in the hole, you can’t remove it without damaging it, so make sure you get it right the first time.
Free Download – 4 Reasons Why Your Concrete Is Taking Forever to Dry
Mistake #4: Trying to Recover and Reuse an RH Sensor
The Rapid RH L6 Smart Sensors are designed for single use. You can’t remove them without damaging them. Even if you manage to remove them with the sleeve intact, the sensors are very sensitive and they can’t be guaranteed to be calibrated accurately after that kind of handling. The Rapid RH 5.0 Smart Sensors are reusable and have the ability to be verified for correct calibration. Calibration for all sensors is essential for accurate testing and the requirements for calibration are detailed in the ASTM F2170 standard.
Mistake #5: Waiting 72 Hours After Installing RH Sensors to Take Readings
72 hours is a long time, especially if it’s not necessary. The original ASTM standard called for an equilibration period of 72 hours, but in 2018 it was slashed to 24 hours. Big difference! It pays to stay up on things, and one way you can do that is to subscribe to the Wagner Meters concrete flooring newsletter at www.rapidrh.com. If there’s ever a disagreement, don’t argue about it. Instead, consult the document, ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes, which you should always have with you while you’re on site.
How to Avoid These Common Mistakes
Here are some simple and easy ways to avoid these common mistakes with your concrete RH testing.
You can increase your understanding and skill in concrete moisture testing with training and certification from ICRI, through their Certified Concrete Slab Moisture Testing Technician (CCSMTT) Certification Program. You can find them at www.icri.org.
Another way to avoid mistakes is to always carry a copy of ASTM F2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs Using in situ Probes with you whenever you’re on the job.
Keep wagnermeters.com bookmarked to access an extensive library of RH testing articles and reference materials.
When in doubt, give us a call at (541) 291-5123. Our courteous and professional support staff would love to help you avoid a disaster beforehand rather than help you pick up the pieces afterward.
Jason has 20+ years’ experience in sales and sales management in a spectrum of industries and has successfully launched a variety of products to the market, including the original Rapid RH® concrete moisture tests. He currently works with Wagner Meters as our Rapid RH® product sales manager.
Last updated on February 11th, 2022